Thông tin kỹ thuật:


ATAGO Digital Bench-top Refractometers are designed to be highly accurate and provide reliable measurements while facilitating a simple measurement method for the operator. When compared to analog and Abbe Refractometers, the large digital readout makes reading the measurement value faster and easier.

RX-α series
 
RX-i series

The world’s highest standard of technology now
available with touch screen.

 
 
Automatic Digital Refractometer RX-5000i-Plus

The most accurate refractometer in the world is now even more stylish, smart, and functional.
Featuring intuitive touch screen technology, the new RX-i series makes navigation and selection a breeze.
The RX-5000i-Plus measures with the same accuracy level as the RX-5000α-Plus - ±0.010% Brix and ±0.00002 nD.
The RX-i series come with newly added functions, such as USB flash drive and self-diagnosis capability.
This product comes standard with a two (2) year limited warranty against manufacturer’s defects from the date of the original purchase. This warranty does not cover or apply to the touchscreen. The warranty period can be extended to three (3) years
if the product is registered with ATAGO.


 

RS-232C Interface External temperature samples User scales can be inputted Measurement at a set temperature Calibration with water Digital display AC outlet (AC100 to 240V) Refractive index scale
Model RX-5000i-Plus Cat.No. 3275
Measurement Range Refractive index (nD) : 1.32422 to 1.58000
Brix : 0.000 to 100.000%
( 5 to 75°C ATC)
Minimum indication Refractive index (nD) : 0.00001
Brix : 0.005%
Temperature: 0.01°C
Measurement Accuracy Refractive index (nD) :
±0.00002
Brix : ±0.010%
Temperature control range 5.00 to 75.00°C
(No lower than 10°C below the ambient temperature and no higher than 55°C above the ambient temperature)
Repeatability Refractive index : ±0.00001 Brix : ±0.010% Power Supply AC100V to 240V, 50/60Hz
Power consumption 90VA Dimensions & weight 37×26×14cm, 6.6kg
(Main Unit only)
Mode MODE-1: Displays the measurement value once the sample reaches the target temperature.
MODE-2: Measures refractive index and temperature at fixed intervals and displays the estimated measurement value at the target temperature.
MODE-3: The thermo-module can be turn off. Without temperature control, the measurement value is displayed in 4 seconds after the START key is pressed.
MODE-S: Displays the measurement value once a certain level of sample stability is achieved
Output terminals • Printer (for ATAGO digital printers)
• Computer -USB
Warranty 2 years standard (3 years with product registration ) excluding touchscreen
Optional • Digital Printer DP-63 : Cat.No.3118
•
Digital Printer DP-AD : Cat.No.3123
•
MAGICâ„¢(metal) : RE-56180
•
MAGICâ„¢(resin) : RE-56185
•
Flow cell attachment : RE-56172
•
10% Sucrose (±0.01%) : RE-111001
•
20% Sucrose (±0.01%) : RE-112001
•
30% Sucrose (±0.01%) : RE-113001
•
40% Sucrose (±0.02%) : RE-114002
•
50% Sucrose (±0.02%) : RE-115002
* Calibration Certificate : Contact an ATAGO representative for details.
Parts • Printer paper (regular) for DP-63 : RE-8412
•
Printer paper (long-term storage)for DP-63 : RE-8414
•
Printer paperfor DP-AD : RE-89403
•
Ribbon cassette for DP-AD : RE-89402
• Fan Filter Replacement : RE-58001
Automatic Digital Refractometer RX-5000i

The most accurate refractometer in the world is now even more stylish, smart, and functional.
Featuring intuitive touch screen technology, the new RX-i series makes navigation and selection a breeze.
The RX-5000i measures with the same accuracy level as the RX-5000α ±0.03% Brix and ±0.00004 nD.
The RX-i series come with newly added functions, such as USB flash drive and self-diagnosis capability.
This product comes standard with a two (2) year limited warranty against manufacturer’s defects from the date of the original purchase. This warranty does not cover or apply to the touchscreen. The warranty period can be extended to three (3) years
if the product is registered with ATAGO.



RS-232C Interface External temperature samples User scales can be inputted Measurement at a set temperature Calibration with water Digital display AC outlet (AC100 to 240V) Refractive index scale
Model RX-5000i Cat.No. 3276
Measurement Range Refractive index (nD) : 1.32422 to 1.58000
Brix : 0.00 to 100.00%
( 5 to 75°C ATC)
Minimum indication Refractive index (nD) : 0.00001
Brix : 0.01%
Temperature: 0.01°C
Measurement Accuracy Refractive index (nD) :
±0.00004
Brix : ±0.03%
Temperature control range 5.00 to 75.00°C
(No lower than 10°C below the ambient temperature and no higher than 55°C above the ambient temperature)
Repeatability Refractive index : ±0.00002
Brix : ±0.03%
Power Supply AC100V to 240V, 50/60Hz
Power consumption 90VA Dimensions & weight 37×26×14cm, 6.6kg
(Main Unit only)
Mode MODE-1: Displays the measurement value once the sample reaches the target temperature.
MODE-2: Measures refractive index and temperature at fixed intervals and displays the estimated measurement value at the target temperature.
MODE-3: The thermo-module can be turn off. Without temperature control, the measurement value is displayed in 4 seconds after the START key is pressed.
MODE-S: Displays the measurement value once a certain level of sample stability is achieved
Output terminals • Printer (for ATAGO digital printers)
• Computer -USB
Warranty 2 years standard (3 years with product registration ) excluding touchscreen
Optional • Digital Printer DP-63 : Cat.No.3118
•
Digital Printer DP-AD : Cat.No.3123
•
MAGICâ„¢(metal) : RE-56180
•
MAGICâ„¢ (resin) : RE-56185
•
Flow cell attachment : RE-56172
•
10% Sucrose (±0.01%) : RE-111001
•
20% Sucrose (±0.01%) : RE-112001
•
30% Sucrose (±0.01%) : RE-113001
•
40% Sucrose (±0.02%) : RE-114002
•
50% Sucrose (±0.02%) : RE-115002
* Calibration Certificate : Contact an ATAGO representative for details.
Parts • Printer paper (regular) for DP-63 : RE-8412
•
Printer paper (long-term storage)for DP-63 : RE-8414
•
Printer paperfor DP-AD : RE-89403
•
Ribbon cassette for DP-AD : RE-89402
• Fan Filter Replacement : RE-58001
Automatic Digital Refractometer RX-5000α-Plus

The NEW RX-5000α (alpha)-Plus features improved accuracy over the RX-5000α-Plus, with Brix ±0.010 and nD ±0.00002. The RX-5000α-Plus is an automatic digital refractometer which can set measurement temperature internally and has the following features for measuring the refractive index, Brix or concentration of various liquids accurately and speedily

• Since the RX-5000α-Plus has a thermo-module to control temperature, a constant temperature water bath is not necessary.
• The measurement starts automatically after the sample reaches your targeted temperature.
• The refractive index and Brix at your targeted temperature are speedily displayed.
• High Brix ± 0.01% and refractive index ± 0.00002 accuracy can be obtained.
• The RX-5000α-Plus displays the top-and-bottom-limit-bar for your set control range.
• If the measurement value differs from that of your Standard Liquid or the other refractometer, it can be adjusted in a certain range.
• 60 kinds of user scales can be input according to your sample.
• The RX-5000α-Plus is capable of calling up 30 latest measurements.
This product comes standard with a two (2) year limited warranty against manufacturer’s defects from the date of the original purchase. The warranty period can be extended to three (3) years
if the product is registered with ATAGO.



RS-232C Interface External temperature samples User scales can be inputted Measurement at a set temperature Calibration with water Digital display AC outlet (AC100 to 240V) Refractive index scale
Model RX-5000α-Plus Cat.No. 3266
Measurement Range Refractive index (nD) : 1.32700 to 1.58000
Brix : 0.000 to 100.000%
( 5 to 60°C ATC)
Minimum indication Refractive index (nD) : 0.00001
Brix : 0.005%
Temperature: 0.01°C
Measurement Accuracy Refractive index (nD) :
±0.00002
Brix : ±0.010%
Measurement Temperature 5 to 60°C
Repeatability Refractive index : ±0.00001 Brix : ±0.010% Power Supply AC100V to 240V, 50/60Hz
Power consumption 65VA Dimensions & weight 37×26×14cm, 6.4kg
(Main Unit only)
Mode MODE-1: Displays the measurement value once the sample reaches the target temperature.
MODE-2: Measures refractive index and temperature at fixed intervals and displays the estimated measurement value at the target temperature.
MODE-3: The thermo-module can be turn off. Without temperature control, the measurement value is displayed in 4 seconds after the START key is pressed.
MODE-S: Displays the measurement value once a certain level of sample stability is achieved
Output terminals • Printer (for ATAGO digital printers)
• Computer - RS-232C
Connection to a USB port requires a USB to RS-232 adapter (optional)
Warranty 2 years standard (3 years with product registration )
Optional • Digital Printer DP-RX : Cat.No.3121
• Digital Printer
DP-RD : Cat.No.3122
•
MAGICâ„¢(metal) : RE-56180
•
MAGICâ„¢ (resin) : RE-56185
•
Flow cell attachment for RX-5000α : RE-56172
•
10% Sucrose (±0.01%) : RE-111001
•
20% Sucrose (±0.01%) : RE-112001
•
30% Sucrose (±0.01%) : RE-113001
•
40% Sucrose (±0.02%) : RE-114002
•
50% Sucrose (±0.02%) : RE-115002
* Calibration Certificate : Contact an ATAGO representative for details.
Parts • Cover plate for RX-5000α : RE-6532
•
Printer paper (regular) for DP-62α, DP-RX : RE-8412
•
Printer paper (long-term storage)for DP-62α, DP-RX : RE-8414
•
Printer paperfor DP-RD : RE-89403
•
Ribbon cassette for DP-RD : RE-89402
• Fan Filter Replacement : RE-58001
Automatic Digital Refractometer RX-5000α

The RX-5000α ( alpha ) is an automatic digital refractometer which can set measurement temperature internally and has the following features for measuring the refractive index, Brix or concentration of various liquids accurately and speedily

• Since the RX-5000α ( alpha ) has a thermo-module to control temperature, a constant temperature water bath is not necessary.
• The measurement starts automatically after the sample reaches your targeted temperature.
• The refractive index and Brix at your targeted temperature are speedily displayed.
• High Brix ± 0.03% and refractive index ± 0.00004 accuracy can be obtained.
• The RX-5000α ( alpha ) displays the top-and-bottom-limit-bar for your set control range.
• If the measurement value differs from that of your Standard Liquid or the other refractometer, it can be adjusted in a certain range.
• 60 kinds of user scales can be input according to your sample.
• The RX-5000α ( alpha ) is capable of calling up 30 latest measurements.

*Special model of RX-5000α allows pre-programming of an additional scale (such as honey moisture, inverted sugar%, salt concentration or butyro) in addition to Refractive Index and Brix (%) at customer's request.
This product comes standard with a two (2) year limited warranty against manufacturer’s defects from the date of the original purchase. The warranty period can be extended to three (3) years
if the product is registered with ATAGO.



RS-232C Interface External temperature samples User scales can be inputted Measurement at a set temperature Calibration with water Digital display AC outlet (AC100 to 240V) Refractive index scale
Model RX-5000α Cat.No. 3261
Measurement Range Refractive index (nD) : 1.32700 to 1.58000
Brix : 0.00 to 100.00%
( 5 to 60°C ATC)
Minimum indication Refractive index (nD) : 0.00001
Brix : 0.01%
Temperature: 0.01°C
Measurement Accuracy Refractive index (nD) : ±0.00004
Brix : ±0.03%
Measurement Temperature 5 to 60°C
Repeatability Refractive index : ±0.00002
Brix : ±0.01%
Power Supply AC100V to 240V, 50/60Hz
Power consumption 65VA Dimensions & weight 37×26×14cm, 6.4kg
(Main Unit only)
Mode MODE-1: Displays the measurement value once the sample reaches the target temperature.
MODE-2: Measures refractive index and temperature at fixed intervals and displays the estimated measurement value at the target temperature.
MODE-3: The thermo-module can be turn off. Without temperature control, the measurement value is displayed in 4 seconds after the START key is pressed.
MODE-S: Displays the measurement value once a certain level of sample stability is achieved
Output terminals • Printer (for ATAGO digital printers)
• Computer - RS-232C
Connection to a USB port requires a USB to RS-232 adapter (optional)
Warranty 2 years standard (3 years with product registration )
Optional • Digital Printer DP-RX : Cat.No.3121
• Digital Printer
DP-RD : Cat.No.3122
• Digital printer
DP-62α : Cat.No.3019
•
MAGICâ„¢(metal) : RE-56180
•
MAGICâ„¢ (resin) : RE-56185
•
Flow cell attachment for RX-5000α : RE-56172
•
10% Sucrose (±0.01%) : RE-111001
•
20% Sucrose (±0.01%) : RE-112001
•
30% Sucrose (±0.01%) : RE-113001
•
40% Sucrose (±0.02%) : RE-114002
•
50% Sucrose (±0.02%) : RE-115002
* Calibration Certificate : Contact an ATAGO representative for details.
Parts • Cover plate for RX-5000α : RE-6532
•
Printer paper (regular) for DP-62α, DP-RX : RE-8412
•
Printer paper (long-term storage)for DP-62α, DP-RX : RE-8414
•
Printer paperfor DP-RD : RE-89403
•
Ribbon cassette for DP-RD : RE-89402
• Fan Filter Replacement : RE-58001
Automatic Digital Refractometer RX-5000α-Bev

The NEW RX-5000α-Bev is a re-designed version of the conventional RX-5000α. A flat sample stage replaced the sample well to make it easier to wipe off the sample and to allow for a faster and easier clean up. The RX-5000α-Bev is ideal for measuring beverages and is equipped with all the standard features of the RX-5000α.
This product comes standard with a two (2) year limited warranty against manufacturer’s defects from the date of the original purchase. The warranty period can be extended to three (3) years
if the product is registered with ATAGO.

 

RS-232C Interface External temperature samples User scales can be inputted Measurement at a set temperature Calibration with water Digital display AC outlet (AC100 to 240V) Refractive index scale
Model RX-5000α-Bev Cat.No. 3271
Measurement Range Refractive index (nD) : 1.32700 to 1.58000
Brix : 0.00 to 100.00%
( 5 to 60°C ATC)
Minimum indication Refractive index (nD) : 0.00001
Brix : 0.01%
Temperature: 0.01°C
Measurement Accuracy Refractive index (nD) : ±0.00004
Brix : ±0.03%
Measurement Temperature 5 to 60°C
Repeatability Refractive index : ±0.00002
Brix : ±0.01%
Power Supply AC100V to 240V, 50/60Hz
Power consumption 65VA Dimensions & weight 37×26×14cm, 6.4kg
(Main Unit only)
Mode MODE-1: Displays the measurement value once the sample reaches the target temperature.
MODE-2: Measures refractive index and temperature at fixed intervals and displays the estimated measurement value at the target temperature.
MODE-3: The thermo-module can be turn off. Without temperature control, the measurement value is displayed in 4 seconds after the START key is pressed.
MODE-S: Displays the measurement value once a certain level of sample stability is achieved
Output terminals • Printer (for ATAGO digital printers)
• Computer - RS-232C
Connection to a USB port requires a USB to RS-232 adapter (optional)
Warranty 2 years standard (3 years with product registration )
Optional • Digital printer DP-RX : Cat.No.3121
• Digital printer
DP-RD : Cat.No.3122
•
10% Sucrose (±0.01%) : RE-111001
•
20% Sucrose (±0.01%) : RE-112001
•
30% Sucrose (±0.01%) : RE-113001
•
40% Sucrose (±0.02%) : RE-114002
•
50% Sucrose (±0.02%) : RE-115002
* Calibration Certificate : Contact an ATAGO representative for details.
Parts • Cover plate for RX-5000α-Bev : RE-65159
•
Printer paper (regular) for DP-RX : RE-8412
•
Printer paper (long-term storage) for DP-RX : RE-8414
•
Printer paperfor DP-RD : RE-89403
•
Ribbon cassette for DP-RD : RE-89402
• Fan Filter Replacement : RE-58001

Automatic Digital Refractometer RX-7000α

The RX-7000α ( alpha ) is an improved ( upgraded ) model for a measurement range of refractive index and measurement temperature of an RX-5000α ( alpha ). The thermo module for constant temperature is equipped.
It is best for measuring oils and fats of high melt point, higher refractive index perfumes, organic solvents, etc. The RX-7000α ( alpha ) has the manual calibration facility which compensate difference in standard liquids and measurement values by other refractometers.
This product comes standard with a two (2) year limited warranty against manufacturer’s defects from the date of the original purchase. The warranty period can be extended to three (3) years
if the product is registered with ATAGO.




RS-232C Interface User scales can be inputted Measurement at a set temperature External temperature samples High temperature samples Calibration with water Digital display AC outlet (AC100 to 240V) Refractive index scale
Model RX-7000α Cat.No. 3262
Measurement Range Refractive index (nD)
1.3250 to 1.7000
Brix 0.00 to 100.0%
(ATC : 5 to 70°C)
Minimum Indication 0.0001or 0.00001
(by selection)
Brix 0.1% or 0.01%
(by selection)
Temperature: 0.01°C
Measurement Accuracy Refractive index (nD) ±0.0001
Brix ±0.1%
Measurement Temperature 5 to 70°C
Repeatability Refractive index : ±0.00005
Brix : ±0.02%
Power Supply AC100V to 240V, 50/60Hz
Power consumption 65VA Dimensions & weight 37×26×14cm, 6.9kg
(Main Unit only)
Mode MODE-1: Displays the measurement value once the sample reaches the target temperature.
MODE-2: Measures refractive index and temperature at fixed intervals and displays the estimated measurement value at the target temperature.
MODE-3: The thermo-module can be turn off. Without temperature control, the measurement value is displayed in 4 seconds after the START key is pressed.
MODE-S: Displays the measurement value once a certain level of sample stability is achieved
Output terminals • Printer (for ATAGO digital printers)
• Computer - RS-232C
Connection to a USB port requires a USB to RS-232 adapter (optional)
Warranty 2 years standard (3 years with product registration )
Optional • Digital Printer DP-RX : Cat.No.3121
• Digital Printer
DP-RD : Cat.No.3122
• Digital Printer
DP-62α : Cat.No.3019
•
MAGICâ„¢(metal) : RE-56180
•
MAGICâ„¢ (resin) : RE-56185
•
Flow cell attachment for RX-7000α : RE-56173
•
10% Sucrose (±0.01%) : RE-111001
•
20% Sucrose (±0.01%) : RE-112001
•
30% Sucrose (±0.01%) : RE-113001
•
40% Sucrose (±0.02%) : RE-114002
•
50% Sucrose (±0.02%) : RE-115002
* Calibration Certificate : Contact an ATAGO representative for details.
Parts • Cover plate for RX-7000α : RE-6532
•
Printer paper (regular) for DP-62α, DP-RX : RE-8412
•
Printer paper (long-term storage) for DP-62α, DP-RX : RE-8414
•
Printer paperfor DP-RD : RE-89403
•
Ribbon cassette for DP-RD : RE-89402
• Fan Filter Replacement : RE-58001
Automatic Digital Refractometer RX-9000α

The RX-9000α is a fully automatic digital refractometer with the highest level of accuracy of its kind.
Designed with a wide measurement range, measurement temperature range, and highest measurement accuracy, this instrument is suitable for multiple sample types ; such as measuring oils and fats with high melting points, aroma oils of high refractive index and organic solvents, meeting demands for high accuracy measurements.
The RX-9000α has a built-in Peltier thermo module for maintaining a constant sample temperature while taking measurements. Manual calibration is also possible to adjust to standard liquid values and to correct differences in measurement values between instruments.
This product comes standard with a two (2) year limited warranty against manufacturer’s defects from the date of the original purchase. The warranty period can be extended to three (3) years
if the product is registered with ATAGO.

 

RS-232C Interface User scales can be inputted Measurement at a set temperature External temperature samples High temperature samples Calibration with water Digital display AC outlet (AC100 to 240V) Refractive index scale
Model RX-9000α Cat.No. 3263
Measurement Range Refractive index (nD) 1.32500 to 1.70000
Brix 0.00 to 100.00%
(ATC : 5 to 70°C)
Minimum Indication Refractive index (nD):0.00001 or 0.0001 (by selection)
Brix 0.01% or 0.1%
(by selection)
Temperature: 0.01°C
Measurement Accuracy Refractive index (nD) : ±0.00004
(nD 1.33299 to1.42009 at Measurement Temperature 10.00 to 30.00°C )
Refractive index (nD) : ±0.00010 (For ranges other than the above)
Brix±0.03% (Brix 0.00 to 50.00% at Measurement Temperature 10.00 to 30.00°C )
Brix±0.05% (Brix 50.01 to 95.00% at Measurement Temperature 10.00 to 30.00°C )
Brix±0.10% (For ranges other than the above, with Sucrose solution by MODE1)
Repeatability Refractive index (nD) : ±0.00002
(nD 1.33299 to1.42009 at Measurement Temperature 10.00 to 30.00°C )
Refractive index (nD) : ±0.00005 (For ranges other than the above)
Brix±0.01% (Brix 0.00 to 50.00% at Measurement Temperature 10.00 to 30.00°C )
Brix±0.02% (For ranges other than the above, with Sucrose solution by MODE1)
Measurement Temperature 5 to 70°C Power Supply AC100V to 240V, 50/60Hz
Power consumption 65VA Dimensions & weight 37×26×14cm, 6.9kg
(Main Unit only)
Mode MODE-1: Displays the measurement value once the sample reaches the target temperature.
MODE-2: Measures refractive index and temperature at fixed intervals and displays the estimated measurement value at the target temperature.
MODE-3: The thermo-module can be turn off. Without temperature control, the measurement value is displayed in 4 seconds after the START key is pressed.
Output terminals • Printer (for ATAGO digital printers)
• Computer - RS-232C
Connection to a USB port requires a USB to RS-232 adapter (optional)
Warranty 2 years standard (3 years with product registration )
Optional • Digital Printer DP-RX : Cat.No.3121
• Digital Printer
DP-RD : Cat.No.3122
•
MAGICâ„¢(metal) : RE-56180
•
MAGICâ„¢ (resin) : RE-56185
•
Flow cell attachment for RX-9000α : RE-56173
•
10% Sucrose (±0.01%) : RE-111001
•
20% Sucrose (±0.01%) : RE-112001
•
30% Sucrose (±0.01%) : RE-113001
•
40% Sucrose (±0.02%) : RE-114002
•
50% Sucrose (±0.02%) : RE-115002
* Calibration Certificate : Contact an ATAGO representative for details.
Parts • Cover plate for RX-9000α : RE-6532
•
Printer paper (regular) for DP-RX : RE-8412
•
Printer paper (long-term storage)for DP-RX : RE-8414
•
Printer paper for DP-RD : RE-89403
•
Ribbon cassette for DP-RD : RE-89402
• Fan Filter Replacement : RE-58001
Automatic Digital Refractometer RX-007α (alpha)

The NEW RX-007α (alpha) is suitable for measuring water soluble samples with very low concentrations (5.000% or less) such as tea (green tea, black tea, oolong tea) and low sugar beverages at a very high accuracy of ±0.005%.
This product comes standard with a two (2) year limited warranty against manufacturer’s defects from the date of the original purchase. This warranty does not cover or apply to the prism. The warranty period can be extended to three (3) years
if the product is registered with ATAGO.




RS-232C Interface External temperature samples User scales can be inputted Measurement at a set temperature Calibration with water Digital display AC outlet (AC100 to 240V) Refractive index scale
Model RX-007α Cat.No. 3921
Measurement Range Brix 0.000 to 5.000%
Refractive index (RI)
1.330150 to 1.341500
Minimum Indication Brix 0.001%
Refractive index (RI) 0.000001
Temperature 0.01°C
Measurement Accuracy Brix ±0.005%, Refractive index (RI) ±0.000010 (at 20°C)
(under specified ambient temperature and constant temperature)
Measurement Temperature 15.00 to 30.00°C Power Supply AC100V to 240V, 50/60Hz
Mode 2 types Dimensions & Weight 37×26×14cm, 6.9kg
(Main Unit only)
Power consumption 85VA
Output Terminals • Printer (for ATAGO digital printers)
• Computer - RS-232C
Connection to a USB port requires a USB to RS-232 adapter (optional)
Warranty 2 years standard (3 years with product registration ) excluding prism
Optional • Digital Printer DP-RX : Cat.No.3121
• Digital Printer
DP-RD : Cat.No.3122
* Calibration Certificate : Contact an ATAGO representative for details.
Parts • Cover plate for RX-007α : RE-56157
•
Printer paper (regular) for DP-RX : RE-8412
•
Printer paper (long-term storage)for DP-RX : RE-8414
•
Printer paperfor DP-RD : RE-89403
•
Ribbon cassette for DP-RD : RE-89402
• Fan Filter Replacement : RE-58001
Digital Refractometer RX-5000

The RX-5000 combines nozzle for connect a water bath instead of built -in thermo module.The RX-5000 is equipped with all the standard features of the RX-a series.
This product comes standard with a two (2) year limited warranty against manufacturer’s defects from the date of the original purchase. The warranty period can be extended to three (3) years
if the product is registered with ATAGO.



RS-232C Interface User scales can be inputted Measurement at a set temperature External temperature samples Calibration with water Digital display AC outlet (AC100 to 240V) Refractive index scale
Model RX-5000 Cat.No. 3281
Measurement Range Refractive index (nD) 1.32700 to 1.58000
Brix 0.00 to 100.00%
Minimum Indication Refractive index (nD) 0.00001%
Brix 0.01%
Measurement Accuracy Refractive index (nD) ±0.00004
Brix ±0.03%
Measurement Temperature 5 to 60°C
Repeatability Refractive index : ±0.00002
Brix : ±0.01%
Power Supply AC100 to 240V, 50/60Hz
Ambient Temperature 5 to 40°C Dimensions & weight 37×26×14cm, 6.4kg
(Main Unit only)
Power consumption 30VA
Output terminals • Printer output ( Digital printer DP-RX is available as an Optional. )
• Computer - RS-232C
Connection to a USB port requires a USB to RS-232 adapter (optional)
Warranty 2 years standard (3 years with product registration )
Optional • Digital printer DP-RX : Cat.No.3121
• Digital Printer
DP-RD : Cat.No.3122
•
10% Sucrose (±0.01%) : RE-111001
•
20% Sucrose (±0.01%) : RE-112001
•
30% Sucrose (±0.01%) : RE-113001
•
40% Sucrose (±0.02%) : RE-114002
•
50% Sucrose (±0.02%) : RE-115002
* Calibration Certificate : Contact an ATAGO representative for details.
Parts • Cover plate for RX-5000 : RE-6532
• Tube band : RE-8507
•
Printer paper (regular) for DP-62α, DP-RX : RE-8412
•
Printer paper (long-term storage) for DP-62α, DP-RX : RE-8414
•
Printer paper for DP-RD : RE-89403
•
Ribbon cassette for DP-RD : RE-89402
Digital Printer DP-62

The DP-62 is a printer for Digital Refractometer RX-5000. It automatically prints out the number of samples, measurement value for refractive index (nD or nDt), Brix (%), concentration (%) (one of user scales), and measurement temperature whenever the refractometer completes measurement.



Model DP-62 Cat.No. 3018
Printing method Thermal dot printing Power Supply DC8.5V from the refractometer
Power consumption 13VA Dimensions & weight 17×16×7cm, 580g
(Main Unit only)
Optional * Calibration Certificate : Contact an ATAGO representative for details.
Parts • Printer paper (regular) for DP-62 : RE-8412
•
Printer paper (long-term storage) for DP-62 : RE-8414
Digital Printer DP-62α

The DP-62α (alpha) is a printer for Automatic Digital Refractometer RX-5000α (alpha), RX-7000α (alpha). It automatically prints out the number of samples, measurement value for refractive index (nD or nDt), Brix (%), concentration (%) (one of user scales), and measurement temperature whenever the refractometer completes measurement.



Model DP-62α Cat.No. 3019
Printing method Thermal dot printing Power Supply DC8.5V from the refractometer
Power consumption 13VA Dimensions & weight 17×16×7cm, 580g
(Main Unit only)
Optional * Calibration Certificate : Contact an ATAGO representative for details.
Parts • Printer paper (regular) for DP-62α : RE-8412
•
Printer paper (long-term storage)for DP-62α : RE-8414
Digital Printer DP-RX

The DP-RX is suitable for RX-5000α having serial No. 052601 onwards and RX-7000α having serial No. 051301 onwards. It automatically prints out the number of samples, measurement value for refractive index (nD or nDt), Brix (%), concentration (%) (one of user scales), and measurement temperature whenever the refractometer completes measurement.



Model DP-RX Cat.No. 3121
Printing method Thermal dot printing Power Supply From AC adapter ( Input voltage:AC100 to 240V )
Power consumption 13VA Dimensions & weight 17×16×7cm, 580g
(Main Unit only)
Optional * Calibration Certificate : Contact an ATAGO representative for details.
Parts • Printer paper (regular) for DP-RX : RE-8412
•
Printer paper (long-term storage)for DP-RX : RE-8414
Digital printer DP-RD

The DP-RD is a printer for Digital Refractometer RX-α series. It automatically prints out the number of samples, measurement value for refractive index (nD or nDt), Brix (%), concentration (%) (one of user scales), and measurement temperature whenever the refractometer completes measurement. The DP-RD uses regular rolled plain paper (not thermal).



Model DP-RD Cat.No. 3122
Printing method Impact dot printing Power Supply From AC adapter ( Input voltage:AC100 to 240V )
Power consumption 7VA Dimensions & weight 11×18×9cm, 470g
(Main Uint only)
Optional * Calibration Certificate : Contact an ATAGO representative for details.
Parts • Printer paperfor DP-RD : RE-89403
•
Ribbon cassette for DP-RD : RE-89402
».iOYõfy[fW,Ö,à,Ç,é GO TOP
Digital Printer DP-63

The DP-63 is a printer for Digital Refractometer RX-i series. It automatically prints out Angle of rotation, International sugar scale, Specific optical rotation, Concentration, Purity, Length of observation tube, Measurement temperature, Sample number Date, Month, Year and Time.



 
Model DP-63 Cat.No. 3118
Printing Method Thermal dot printing Power Supply AC adapter (Input voltage : AC100 to 240V)
Power Consumption 13VA Dimensions & Weight 17×16×7cm, 580g
(Main Unit only)
Optional * Calibration Certificate : Contact an ATAGO representative for details.
Parts • Printer paper (regular) for DP-63 : RE-8412
•
Printer paper (long-term storage)for DP-63 : RE-8414

Digital printer DP-AD

The DP-AD is a printer for Digital Refractometer RX-i series. It automatically prints out Angle of rotation, International sugar scale, Specific optical rotation, Concentration, Purity, Length of observation tube, Measurement temperature, Sample number Date, Month, Year and Time.The DP-AD uses regular rolled plain paper (not thermal).



 
Model DP-AD Cat.No. 3123
Printing method Impact dot printing Power Supply From AC adapter ( Input voltage:AC100 to 240V )
Power consumption 7VA Dimensions & weight 11×18×9cm, 470g
(Main Uint only)
Optional * Calibration Certificate : Contact an ATAGO representative for details.
Parts • Printer paperfor DP-AD : RE-89403
•
Ribbon cassette for DP-AD : RE-89402

::| Các sản phẩm cùng loại
Khúc xạ kế để bàn ABBE model NAR-Series   Khúc xạ kế Ä‘o độ đường hiển thị số model PAL-Series   Khúc xạ kế Ä‘o độ mặn hiển thị số model ES-421; PAL-ES2 & PAL-ES3
 
Khúc xạ kế Ä‘o độ mặn (Mater series)   Máy Ä‘o ánh sáng Ä‘iện tá»­ hiện số model MW700   Máy cất nước má»™t lần 4 lít/giờ
 
Cân xác định độ ẩm model MB25 (Hàng có sẵn)   Cân xác định độ ẩm model MB45 (Hàng có sẵn)   Máy lắc ngang Ä‘iện tá»­ hiện số model SSL2
 
Máy lắc tròn Ä‘iện tá»­ hiện số model SSL1   Máy khuấy từ gia nhiệt model CB162   Máy lắc Vortex model SA8
 
Máy Ä‘o oxy hòa tan cầm tay Ä‘iện tá»­ hiện số model MW600   Máy Ä‘o pH/Nhiệt độ cầm tay Ä‘iện tá»­ hiện số model MW102   Bếp gia nhiệt model SLH
 
 
« Quay lại trang trước